Inspection records are retyped
Measured values are written down by hand at the machine and later transferred into a spreadsheet or a system. That ties up time in quality assurance and leaves room for transfer errors.
Medical technology
Whether it is an instrument, an implant component or a precision part for a device, in medical technology the dimensions have to be right, and production and inspection have to be traceable later on. Which records are required differs by product and customer. EVOMECS brings inspection specifications to the workstation, records the results digitally and assigns them to order, workpiece and batch.

From medical technology
Measured values are written down by hand at the machine and later transferred into a spreadsheet or a system. That ties up time in quality assurance and leaves room for transfer errors.
In small series, it has to be clear which parts belong to which batch and how each one was inspected. With paper and separate lists, that takes a great deal of care and effort.
When a drawing or an inspection plan changes, the new version has to apply at every workstation straight away. If an old sheet is still lying at the machine, parts are inspected against the wrong specifications.
An operation is completed even though a planned inspection is missing. That may only come to light when the documentation for the batch is being compiled.
For traceability, the inspection result alone is often not enough. The question is also which program version and which tools a part was made with, and that information usually sits somewhere else.
For quality assurance, the lever lies where inspections are created on paper today. In EVOMECS, inspection characteristics and specifications are defined once per operation and appear at the workstation at the point where the inspection is due. Employees record the measured values directly, and digital checklists secure checks that are confirmed rather than measured. Every result is assigned to the order, operation, workpiece and the person who inspected.
With Shopfloor Professional, traceability reaches further. Which NC program and which tools were used for a workpiece is assigned to the production order. In the event of a query or complaint, it is possible to trace the conditions under which a part was made, without gathering records from different folders.
EVOMECS is not a complete quality management system for medical technology and does not replace validation. Which data is captured depends on edition, machine and interface.
Example illustration
Worker self-inspection · Instrument shaft · Operation 30
| Characteristic | Target | Actual | Result |
|---|---|---|---|
| Shaft Ø 4 h6 | 3.992–4.000 | 3.996 | OK |
| Overall length | 120.00 ± 0.05 | 120.02 | OK |
| Roughness Ra | ≤ 0.4 µm | 0.3 µm | OK |
| Visual check for burrs | burr-free | burr-free | OK |
Stored in the order – with batch, operation, time and the person who inspected.
Tracing back from the workpiece
Example workflow
Illustrative example, not a customer reference. The exact workflow depends on edition, machines and existing systems.
Inline quality management is already part of Shopfloor Light. Many companies therefore start with digital inspections and feedback at the workstation. Once the tool process and NC execution are integrated, traceability grows step by step back to program and tool.

Benjamin Neubauer
Chief Executive Officer (CEO), EVOMECS
How to get started
In the first meeting we show you EVOMECS in a live demo tailored to your company. Afterwards you can try EVOMECS free of charge for two weeks in your own demo system.
First meeting: 30 minutes · online · free of charge