At a glance
- Heidenhain controls from the TNC 426 on can be connected.
- With option 18 (HEIDENHAIN DNC) you get the complete data picture.
- Without option 18, the connection runs via LSV2, with a somewhat smaller data scope.
- On the TNC7, option 18 is mandatory because LSV2 is no longer available there.
- You need no additional hardware.
Interface and prerequisites
| Control | Interface | Prerequisite |
|---|---|---|
| Heidenhain with option 18 | HeidenhainDNC | Software option 18 (HEIDENHAIN DNC), Ethernet |
| Heidenhain TNC7 | HeidenhainDNC | Option 18 is mandatory, as LSV2 is no longer available on the TNC7 |
| Heidenhain from TNC 426 without option 18, e.g. iTNC 530 | LSV2 (available without an additional option) | Ethernet |
How to prepare the control
- 1Clarify option 18You clarify whether option 18 is enabled on the control. If in doubt, your machine manufacturer can tell you. It is mandatory on the TNC7; older controls also work without it.
- 2Connect the networkThe control is connected to your company network via Ethernet so that the EVOMECS Hub can reach it.
- 3Note the IP addressYou note the IP address of the control. You need it when setting up the machine in EVOMECS.
- 4Helper application on the hubFor Heidenhain controls, an additional helper application runs on the hub server, as a Windows process or container. [INHALT: Support/Technik – helper application on the loan device and on your own server]
Which data you get
| Connection | Data scope |
|---|---|
| HeidenhainDNC with option 18 | Complete – status, active program, overrides and actual feed, spindle speed, cycle time, alarms with number, text and timestamp, remaining tool life |
| LSV2 without option 18 | Status, active program with block number, overrides, error messages with timestamp, remaining tool life from the tool table |
Read on
Open technical questions are best clarified directly – with your machine list and your IT at the table.
Arrange a technical call
Benjamin Neubauer
Chief Executive Officer (CEO), EVOMECS
How to get started
Your demo – tailored to your production.
In the first meeting we show you EVOMECS in a live demo tailored to your company. Afterwards you can try EVOMECS free of charge for two weeks in your own demo system.
- 1First meeting · 30 minutes onlineWe introduce EVOMECS, show it in a short live demo and clarify your needs.
- 2Your demo systemIf you wish, we set up your own demo system in Shopfloor Light – with your machines and sample data. You receive the invitation by email.
- 3Try it yourself for two weeksYou and your colleagues try out how orders, feedback, machine status and downtimes work together. Free of charge, without installation and without connecting machines.
- 4Connect your machinesIn Shopfloor Light you connect your machines yourself using our guide. If you wish, we support you in a pilot project.
First meeting: 30 minutes · online · free of charge