Machine controls
Machine connectivity
Which controls EVOMECS connects and how, what is required and which data you get from each machine. Written for maintenance, production management and IT who want a realistic view of their machine park.
At a glance
- EVOMECS uses whatever interface your control offers – OPC UA is not a requirement.
- SINUMERIK 840D sl is connected directly via S7, with no additional licence.
- On the Heidenhain TNC7, software option 18 is mandatory.
- Older machines can be connected too – via a media converter or a signal tap.
- The data scope depends on the control and is documented per machine before the project.
- Modern controls with Ethernet usually need no additional hardware.
- Machines stay in the local network, even when EVOMECS runs in the cloud.
- Data is exchanged in both directions – programs and tool data to the machine, states, alarms and measurement results back.
Principles
- Connection via whatever interface is available. EVOMECS does not require a particular interface such as OPC UA but uses what the control offers. Where the OPC UA option is already licensed on the control, OPC UA is used in production as well.
- Data exchange in both directions. EVOMECS does not only read data but also brings NC programs, tool data and order and pallet data to the machine. This is handled by the MachinePulse interface for machine data (standard from Light), ToolBridge for tool data (standard from Essentials), and NCBridge and PartBridge for NC programs and workpieces (standard from Professional).
- Older machines can be connected too. Controls without Ethernet are connected via a media converter, machines without a usable interface via a signal tap.
- The data scope depends on the control. Depending on the interface, it ranges from a simple "running/stopped" status to the full picture with program, overrides, alarms and tool life.
- Additional hardware is the exception. Modern controls with Ethernet usually need no hardware. You can obtain the hardware for signal taps and media converters through EVOMECS or procure it yourself.
- Machines stay in the local network. Even when EVOMECS runs in the cloud, the EVOMECS Hub talks to the controls exclusively inside your company network.
Controls and interfaces
The overview shows how EVOMECS connects common controls. For your specific control, the Machine Check shows the same details.
| Control | Interface | Prerequisites | Additional hardware |
|---|---|---|---|
| Siemens SINUMERIK 840D sl | S7 (ISO-on-TCP, port 102) directly to NCK and PLC; alternatively OPC UA if licensed | Ethernet port on the NCU, port 102 open in the NCU firewall. No "Access MyMachine / OPC UA" licence and no specific Operate version required | None |
| Siemens SINUMERIK 840D pl / 810D (older generation) | S7 via MPI/Profibus | Ethernet port on the control, otherwise a media converter | Possibly a media converter from MPI/Profibus to Ethernet (e.g. Helmholz NETLink PRO Compact) |
| Heidenhain TNC7 | HeidenhainDNC | Software option 18 (HEIDENHAIN DNC) is mandatory, as LSV2 is no longer available on the TNC7 | None |
| Heidenhain from TNC 426 without option 18 (e.g. iTNC 530) | LSV2 (available without an additional option) | Ethernet port | None |
| Heidenhain with option 18 | HeidenhainDNC | Option 18 | None |
| Heidenhain MillPlus | No online protocol; status via signal tap, NC programs via the control's network drive | Potential-free contacts on the PLC or signal tower | IoT gateway with a 24 V input/output module (e.g. SIMATIC IOT2050) |
| Fanuc (e.g. Series 0i, 31i) | FOCAS2 via Ethernet | FOCAS2 enabled (usually available on newer controls, check on older ones) | None; otherwise enabling the option or an Ethernet/Data Server board |
| Control without a usable interface | Signal tap | Potential-free contacts on the PLC or signal tower | IoT gateway with a 24 V input/output module (e.g. SIMATIC IOT2050) |
EVOMECS connects Heidenhain controls from the TNC 426 to the TNC7, via HeidenhainDNC or LSV2 depending on the control and option. For this, an additional helper application runs on the Hub server, as a Windows process or container. Siemens SINUMERIK ONE and 828D as well as Andron controls are also implemented; interface and requirements are defined per machine.
Data exchange in both directions
Which data is transferred in detail depends on the control and the connection type.
| Direction | Data |
|---|---|
| To the machine | NC programs, tool data, order and pallet data |
| Back from the machine | Program status, alarms, tool life, measurement results |
Further technologies and automation
Besides milling machines, EVOMECS connects further technologies and automation components. The overview shows the current status.
| Technology or component | Status |
|---|---|
| Milling with Heidenhain, Siemens or Fanuc control | In production use |
| Die-sinking EDM | In production use |
| Wire EDM | In production use; further controls in development |
| Grinding | In development |
| Robots and handling | In production use |
| Washing systems | In production use |
| Coordinate measuring machines | In production use |
For a specific production, a connection is only confirmed after the technical proof on your machine and automation landscape.
Data point catalogue
EVOMECS can capture up to 19 parameters per machine. The next table shows which of them your control delivers.
| Group | Data points |
|---|---|
| Status | Machine status (running/stopped), operating mode, active NC program |
| Tool | Tool in use, tool life |
| Motion | Feed rate set and actual, feed override, rapid traverse active, rapid override, spindle speed set and actual, spindle override |
| Counters and times | Operating hours, spindle hours, part count, cycle time per part |
| Fault | Fault messages, downtime reasons |
Override means the actual position of the dial in percent, separately for feed, rapid traverse and spindle – not the programmed value.
Data scope per connection type
| Connection type | Typical data scope |
|---|---|
| SINUMERIK 840D sl via S7 | Full – status, operating mode, active program, actual feed, actual speed, all three overrides, alarms with number, text and timestamp, remaining tool life, counters and cycle time. Multiple spindles (main, counter and tool spindle) are read separately |
| Older SINUMERIK via MPI/Profibus | Status, program, overrides and alarms |
| Heidenhain TNC7 via HeidenhainDNC | Full – status, active program, overrides and actual feed, spindle speed, cycle time, alarms with number, text and timestamp, remaining tool life |
| Heidenhain from TNC 426 via LSV2 (e.g. iTNC 530) | Status, active program with block number, overrides, error messages with timestamp, remaining tool life from the tool table |
| Fanuc via FOCAS2 | Status, operating mode incl. single block, program, actual and set values, overrides, alarms in plain text, counters and times |
| Signal tap | Status running/stopped, collective fault with timestamp, cycle time from status changes; no program name, no overrides, no alarm texts, no tool life |
Downtime reasons, cycle times and alarms
- No control delivers downtime reasons. The operator records them at the workstation in the logbook, from a selection list per workstation with an optional or mandatory comment. This works on every machine, regardless of the control. EVOMECS additionally derives the technical cause from alarm, operating mode, program end and feed hold.
- EVOMECS determines cycle times from status changes and the running program – even on machines connected only via a signal tap.
- Alarm types are only delivered as far as the control outputs them. Otherwise EVOMECS captures alarm number, text and timestamp.
Machine data and works agreements
In many companies a works agreement governs which machine data may be captured. A per-machine list of the data points that can actually be captured provides a transparent basis for it. Data points typically covered by such agreements – feed rates, cycle times, remaining tool life, alarm type and timestamp – are available on fully connected controls.
More on this in the article "Machine data collection and the works council".
Getting tool data to the machine
One of three ways is defined per machine.
| Way | How it works | Note |
|---|---|---|
| Directly into the control | EVOMECS writes the tool table, lengths, radii and tool life directly into the control's tool management | In productive use on SINUMERIK 840D sl. On Heidenhain via LSV2, the tool table (TOOL.T) is transferred in both directions |
| Via a control system or cell controller | Tool data runs through an existing system that already transfers tool data | See cell controllers and control systems |
| By hand scanner | Every tool carries a label with a QR code, Data Matrix code or RFID. It is scanned at the machine and the data is transferred to the machine | No setup in parallel with machining required. Fallback for machines without writable tool management |
Technical details for control experts
For those who want the details – SINUMERIK 840D sl and Fanuc FOCAS2.
- SINUMERIK 840D sl: status, operating mode, NC program, actual feed, actual speed, overrides and alarm list are read in productive use. Set values, single block, rapid traverse (G0) and active tool come from the BTSS variables of the NCK.
- SINUMERIK 840D sl: tool life requires active tool management with tool life monitoring. Counters and times come from NC system variables (including $AC_OPERATING_TIME, $AC_CUTTING_TIME, $AC_TOTAL_PARTS, $AC_CYCLE_TIME); time and part counters must be enabled in MD 27860 / 27880.
- SINUMERIK 840D sl: the control does not keep its own spindle hour counter; tool cutting time serves as spindle hours. Fault messages arrive as an alarm number with fill text, and EVOMECS resolves the plain text via the alarm number.
- Fanuc FOCAS2: status, program, actual values and alarms come directly from the standard FOCAS functions, set values and rapid traverse from the modal data. The overrides are held in PMC signals whose addresses are specific to the machine manufacturer.
- Fanuc FOCAS2: counters and times come from NC parameters. Part counting requires a configured counting M code.
Frequently asked questions about machine connectivity
Do we need OPC UA to connect machines to EVOMECS?
No. EVOMECS uses the interface your control offers – on the SINUMERIK 840D sl, for example, S7 directly to NCK and PLC, without an OPC UA licence. Where the OPC UA option is already licensed, OPC UA is used in production as well.
Can we connect older machines as well?
Yes. Controls without Ethernet are connected via a media converter, machines without a usable interface via a signal tap on the PLC or signal tower. The data scope is then smaller – with a signal tap, for example, status, collective fault and cycle time.
Do our machines need internet access?
No. The machines only talk to the EVOMECS Hub in the local network. Even when EVOMECS runs in the cloud, the Hub communicates with the controls exclusively inside your company network.
What happens at the machine if the network or server fails?
Local EVOMECS services at the cell or machine keep the connection to the control and the robot. A running job is completed, new jobs only start again once the server can be reached, and the machine remains manually operable. After reconnecting, state changes are posted retroactively. More on this on the Operation, updates & support page.
Which additional hardware should we plan for?
Modern controls with Ethernet usually need no hardware. Older SINUMERIK controls without Ethernet may need a media converter, a signal tap needs an IoT gateway with a 24 V input/output module. You can obtain this hardware through EVOMECS or procure it yourself.
Where do downtime reasons come from?
No control delivers downtime reasons. The operator records them at the workstation from a selection list – on every machine, regardless of the control. EVOMECS additionally derives the technical cause from alarm, operating mode, program end and feed hold.
How do we know in advance what is possible on our machines?
Before the project we document interface, prerequisites, additional hardware and capturable data points for each machine. Anything that is not clear from the documentation, such as control options or network ports, we clarify together with you and your machine manufacturer.
Read on
- Connecting machines in Shopfloor Light – step by step
- Machine Check – your control in detail
- IT & security – Hub, firewall and cloud
- Operation, updates & support – behaviour on failure
- Machine data collection and the works council
- Implementation checklist – preparing the machine list
- Production and machine data collection in EVOMECS
- Editions – standard interfaces and add-on modules
Open technical questions are best clarified directly – with your machine list and your IT at the table.
Arrange a technical call
Benjamin Neubauer
Chief Executive Officer (CEO), EVOMECS
How to get started
Your demo – tailored to your production.
In the first meeting we show you EVOMECS in a live demo tailored to your company. Afterwards you can try EVOMECS free of charge for two weeks in your own demo system.
- 1First meeting · 30 minutes onlineWe introduce EVOMECS, show it in a short live demo and clarify your needs.
- 2Your demo systemIf you wish, we set up your own demo system in Shopfloor Light – with your machines and sample data. You receive the invitation by email.
- 3Try it yourself for two weeksYou and your colleagues try out how orders, feedback, machine status and downtimes work together. Free of charge, without installation and without connecting machines.
- 4Connect your machinesIn Shopfloor Light you connect your machines yourself using our guide. If you wish, we support you in a pilot project.
First meeting: 30 minutes · online · free of charge